Ro antiscalant data sheet.

Ro antiscalant data sheet Emergency Telephone Number: (800) 424−9300 (Toll Free) (703) 527−3887 Address (Corporate Headquarters): 5640 COX ROAD Glen Allen, VA 23060 This document summarizes the material safety data for BERKO SAFE 106 NSF reverse osmosis antiscalant. EC-RO-16 does not present any significant health or environmental hazards according to its safety data sheet. • Offers superior control of calcium carbonate and calcium sulfate scales. It contains some […] Using RO Antiscalants help to control inorganic scales of calcium, magnesium, barium, strontium, fluoride, iron and silica. Please refer to the Material Safety Data Sheet (MSDS) for the most PermaTreat PC-391T is a highly effective current data and complete information. 5. 50 mPa. 09. It prevents calcium sulfate (CaSO 4) scale precipitation, allowing up to 6 times saturation. Application: Vitec 5100 Antiscalant Datasheet - Free download as PDF File (. 3 Recommended Use Of The Chemical and Restrictions On Use: Reverse osmosis membrane antiscalant Use only as directed on the label. Material Safety Data Sheet Issue Date: 24-AUG-2007 Supercedes: 24-AUG-2007 HYPERSPERSE MDC150 1 Identification of Product and Company Identification of substance or preparation HYPERSPERSE MDC150 Product Application Area Reverse osmosis antiscalant Emergency Telephone (800) 877-1940 Prepared by Product Stewardship Group: 215 355-3300 This document is a safety data sheet for the product WSTS-11, an antiscalant for reverse osmosis systems produced by Water Steam Treatment and Supply Co. This full spectrum antiscalant is also Flocon® Antiscalant water additives, used as pretreatment for Reverse Osmosis systems, are highly effective in preventing membrane scaling. Chemical Feeding and Control. ª º1­;GÚn" …¦ T’M[ wÚ¸) uá A¡&”Š¡#T m‹X ÔqáÂŒ ]Ø3ïÌœ|sßof&é%„7ïÝwïù¾{¾Ÿû½›{óæ kj»y§ y¿£½­¹ å ‡ ¬7o?-Ü)þýàùLéUBÏÖ–·Þ[³´³½­cÃòÆ Caretreat Antiscalant WT® RO is a multipurpose Antiscalant for Reversed Osmosis (RO) and Ultra filtration (UF) systems. Proper precautions should be taken including protective equipment during handling and use. INDION 8113 is not compatible with residual cationic polymers from the pre-treatment. While treatment with an ordinary antiscalants does provide some improvement, the use of Veolia's patented chemistry maximizes efficacy against a broad range of scale-forming SAFETY DATA SHEET 1. Application For maximum effectiveness, Hypersperse MDC700 reverse osmosis system. Firefighting measures are outlined, along with handling and storage recommendations MATERIAL SAFETY DATA SHEET Section 1. Packaging Information Hypersperse MDC700 is a liquid material, available in a wide variety of customized containers and methods. 2014 01. com Vitec 5100® is a broad spectrum, liquid antiscalant and dispersant that is compatible with organic coagulants and effective at low dose rates. It can be injected neat or diluted and used in a wide array of feedwater sources Vitec 3000 has been approved for use in systems producing drinking water by the UK Drinking Water Inspectorate and by NSF International under NSF/ANSI Standard 60. UF / RO / NF / MBR membranes and evaporators • Membrane Sanitizers and non-oxidizing biocides • Preservatives to enhance life of stored membranes • Antiscalants for preventing mineral deposits, inorganic foulants and silica in membrane and thermal evaporation systems. • Defoamers for MED and MSF Thermal Desalination systems done with RO permeate or equivalent quality water for preferably not less than 10% solution. Wear protective clothing as described in Section 8 of this material safety data sheet. 5. The only DuPont-approved and valid version of this Permatreat pc 510t msds is a material safety data sheet (MSDS) for a product called Permatreat pc 510t. The classification is in accordance with the latest editions of international substances lists, and is supplemented by information from technical literature and by information provided by the company. geoenviro@gmail. 6 °C) Density : 1. The product is based on the latest polymer technology. This full spectrum antiscalant is also very effective in high iron and organic waters. Today, our product line includes a full range of state-of-the-art cross-linked polyamide composite membranes manufactured under ISO-9001 certification for consistency in product and service quality. com Get a Quote RO Chemicals Antiscalant Chemical Pure Aqua’s PA0100 antiscalant chemical offers superior quality performance characteristics over a wide range of applications. pdf), Text File (. To prevent release, place container with damaged side up. A dosage projection is required for each system to ANTISCALANT ™ Trademark, Solenis or its subsidiaries or affiliates, registered in various countries 1. Identification Identification Product name: AQUAFEED® 1025 ANTISCALANT Apr 23, 2020 · [custom-specifications] Dosing Guidelines. SO4 RO-TREAT-102 is a polycarboxylate base highly effective liquid antiscalant developed to control scale precipitates within membrane separation systems. It REVERSE OSMOSIS ANTISCALANT Vitec™ 5100 is a multicomponent antiscalant targeted at preventing scale precipitation in larger systems and is particularly cost effective in seawater and municipal reverse osmosis (RO) applications. +31-152-610-900 www. Company and Product Identification 1. This formulation is unique in that it inhibits silica scaling at higher concentration than typical antiscalants, a feature which may allow Product Name: RO Antiscalant Application: RO Treatment WTRD305 is a economical Antiscalent / Antifoulant control agent for reverse osmosis systems. It is recom- Use of the Substance/Mixture : REVERSE OSMOSIS ANTISCALANT. Vitec ™ 3000 is a powerful, wide spectrum, liquid antiscalant and dispersant that is highly effective at low dose rates and in a wide range of feedwaters such as brackish, wastewater, and seawater. Technical Data Sheet. 1 6 / 12 Viscosity, dynamic : ca. 0 mg/l. Biodispersants. A dosage projection is required for each system to determine the proper dosage. New Delhi 4th Floor Veolia's RO membrane antiscalants are pretreatment programs designed to eliminate scale and reduce fouling in membranes systems, regardless of the feedwater source. Page 1 of 4 Material Safety Data Sheet Section 01: Chemical Product Identification Domestic Trade Name: PT401 Antiscalant Synonyms: NA Export Trade Name: PT401 Antiscalant CAS Number: NA APPLICATION values for this product. suspended solids, microorganisms and mineral scale can foul membrane elements. 3 Details of the supplier of the safety data sheet: COMPANY IDENTIFICATION LOCAL COMPANY IDENTIFICATION fact sheet Hypersperse* MDC706 A Material Safety Data Sheet containing detailed RO antiscalant, RO antifoulant, MDC 706 Reverse Osmosis Antiscalant 7mg/L [1] This product is designed to be used off-line and flushed out prior to using the system for drinking water, following manufacturer's use instructions. 1 Identification – Product Name : Vitec ® 4000 1. %PDF-1. aun Find here RO Antiscalant, RO Antiscalant Chemical manufacturers, suppliers & exporters in India. Remarks This document provides safety information for GC-502 Antiscalant, a phosphate and polymer-based chemical used as an antiscalant in reverse osmosis systems at a concentration of 5-10 mg/L. Increase the productvity of your plant by getting your own Pretreat Plus® – 0100 and find out why it is increasingly replacing older water treatment products in the Download Genesys LF Safety data sheet. e¤˜!Îð0EœCbŽ ¼:üI¼ZM SRÃ"¼jèa¢% ¯ zÆÁ ¦V) ÀsÌ‘ *L‘`Ì’ À X x p* ¤ÍH„% 0Qp& Òp& $ðeXª4IàY€K@X‡yàe B «H …y Ä' ¤Å| 8SxULPX¢ ¯ 0Áæ°%i2è a §àÊÁ¹ a ð2ãHáaWP | % q½};¹~¸÷4¹ª«õ´¾®¼ Universal antiscalant product, which can be used for brackish, sea and waste water. Download - HYDREX 4102 Technical Datasheet. The antiscalants will inhibit scale and disperse solid particles. In the event of exposure, flush eyes or skin with water For these reasons, the overall cost of the systems utilized is reduced, whether they be reverse osmosis or nanofiltration, specifically due to the extensive membrane lifespan. 5 %âãÏÓ 1 0 obj > stream xœÍVßOÛ0 ~Gâ ¸Çm/õo;Ò„Ä6 ˆ !@Ú ÚCÖz¥ZIPšJã¿ßçØt4Ê ºiRڋϾï|çóå3ÄÈR–‘#. Caretreat Antiscalant WT® RO inhibits Carbonate and Sulfate scales and Safety Data Sheet RPI-4000B Revision Date: 16. While BWA has made every effort to ensure this information is correct, no responsibility can be accepted by BWA for any loss or liability occasioned by any person acting or refraining from acting as a result of the Advantages. Vitec® 3000 can be injected neat or diluted and can be used in a wide array of feedwater sources. Protect from freezing and from exposure to high temperatures. It retains its performance even in RO concentrate streams containing up to 4 ppm of ferrous iron. PRODUCT INFORMATION SHEET Internet Promotion Version - Not to be treated as original High Silica RO Antiscalant Chemtex’s High Silica RO Antiscalants are specific Anti-scalants for Reverse Osmosis membrane feed water effective in controlling deposition of inorganic scales and higher levels of silica and metal oxides. com Fax. PRODUCT AND COMPANY IDENTIFICATION Product name : PERMATREAT® PC-191T Other means of identification : Not applicable. In the absence of a static mixer RO TREAT 5010™ is a proprietary liquid antiscalant designed to inhibit silica, sulfate, and carbonate scale and disperse colloidal particles in cellulose acetate and polyamide membrane separation systems. Specific symptoms from animal test: Acute toxicity, oral (LD50): Rat > 5000 mg/kg Acute toxicity, dermal (LD50): Rabbit > 5000 mg/kg Membrane Antiscalant PermaTreat 191 is one of the principal antiscalants used by the membrane industry. It is compatible with all of the leading RO membranes. +01 813-248-0573 Website: www. Applications: Membrane Desalination/Reverse Osmosis Vitec® 3000 RO/NF Vitec 3000® is a powerful, broad spectrum, liquid antiscalant and dispersant that is compatible with organic coagulants. It presents health hazard and first aid information, noting the product is not hazardous according to European directives. Identification Identification Product name: AQUAFEED® 1025 ANTISCALANT, ABC7318 Additional identification Chemical name: Polyelectrolyte solution Recommended use and restriction on use Recommended use: Water Treatment Chem Restrictions on use: None identified. The product is shipped in 25kg plastic drums and Elevate your water treatment solutions with Green Dot Limited, your trusted source for top-notch products such as Genesys Antiscalant, a cutting-edge RO Antiscalant developed by Genesys Chemicals. 2022 Print Date: 19. concentration than typical antiscalants, a feature which may allow significantly increased RO system recovery in high silica feed waters. WETICO produces its own specialty chemicals under the ‘berko’ brand name and provides a wide range of products and services to our clients. com Tel. of page 11) 1305 North Florida Avenue Tampa, Florida USA 33602-2902 Toll Free North America 1-888-255-3924 Intl. The product is not Reverse Osmosis Membrane Antiscalant Description Sokalan RO 100 is an aqueous solution of a polycarboxylate with a low molar mass. Since then it has become the pre-ferred method of scale control in thousands of instal-lations throughout the world, including some of the largest potable water plants ever built. Application: Optimum Vitec® 3000 performance is achieved when the chemical is injected downstream of multimedia filters and upstream of cartridge filters. This document is a safety data sheet for the product WSTS-11, an antiscalant for reverse osmosis systems produced by Water Steam Treatment and Supply Co. 36, Vitec® 3000 RO/NF Vitec 3000® is a powerful, broad spectrum, liquid antiscalant and dispersant that is compatible with organic coagulants. Powder. Antiscalants. It lists the product name and manufacturer information in Section 1. Flocon 135 Antiscalant for RO Systems is an aqueous solution of a specialized phosphinocarboxylic acid, highly effective in controlling the deposition of inorganic scale forming salts on membrane surfaces. Œ J­´U". 10. For more information, see the Safety Data Sheet provided with this product. 4636 Somerton Road Trevose, PA 19053 T 215 355-3300, F 215 953 5524 To optimise the performance of RO membrane systems cleaning and servicing are required periodically. PermaTreat PC-391T combines the product reliability of PermaTreat PC-391 with patented TRASAR® Technology for accurate dosage and advanced monitoring and control. lenntech. reverse osmosis (ro) membrane performance can be negatively impacted by impurities that build up on the membrane surface during operations. Consult the Material Safety Data Sheet as the only official source of Environmental and Safety information. Dosing Guidelines: The typical dosage range is between 2 to 5 ppm. Accepta 2091 can be used in reverse osmosis applications where the reject brine silica levels are as high as 230 ppm at 30oC and pH 7. • Compatible with all of the leading RO membranes. ENVIRONMENTAL PRECAUTIONS. Avoid release to the environment. In the absence specific feed water mineral analysis and system design and operating parameters for RO membranes. scale inhibitor developed for reverse osmosis (RO) membrane systems with low flow rates. Use RO permeate for dilution. Title: GE-Hypersperse-antiscalant-antifoulant-MDC-120-775-700-704-AF-250UL-MS1310-Lenntech Author: GE-Lenntech Subject: GE-Hypersperse-antiscalant-antifoulant-MDC-120 fact sheet Hypersperse* MDC150 antiscalant / antifoulant • Certified for use in producing potable water. 3 Details of the supplier of the safety data sheet Solenis Pesetastraat 62 2991 XT Barendrecht Netherlands Page: 7 SAFETY DATA SHEET Revision Date: 03. SAFETY DATA SHEET Revision Date: 09. Recommended use : REVERSE OSMOSIS ANTISCALANT Restrictions on use : Refer to available product literature or ask your local Sales Follow precautions for safe handling described in this material safety data sheet. Chemical Feeding and Control Injection: AWC A-103 should be injected continuously into the RO feedwater line, always downstream of multimedia filters, and preferably downstream of the cartridge filters in the presence of a static mixer. Antiscalants are customized based on the feed water quality and plant design to achieve cost effective maintenance in having less Vitec ™ 5100 is a liquid antiscalant and dispersant targeted at preventing scale precipitation in larger systems and is particularly cost effective in seawater and municipal reverse osmosis (RO) applications. chemtelinc. Injection: AWC A-110 should be injected continuously into the RO feedwater line, always downstream of multimedia filters, and preferably downstream of the cartridge filters in the presence of a static mixer. 2023 SDS Number: R1201600 Sokalan™ RO 100 Antiscalant and Deposit Controller ™ Trademark, Solenis or its subsidiaries or affiliates, registered in various countries 934560 Version: 1. It can be used in reverse osmosis (RO), nano-filtration (NF) and ultra-filtration (UF) system. Injection: AWC A-102 Ultra should be injected continuously into the RO feedwater line, always downstream of multimedia filters, and preferably downstream of the cartridge filters in the presence of a static mixer. RW-21; RW-31; Liquid. Performance Benefits Product Name: RO Antiscalant Application: RO Treatment WTRD305 is a economical Antiscalent / Antifoulant control agent for reverse osmosis systems. +31-152-616-289 info@lenntech. For almost 20 years PermaTreat 191 has found application as an antiscalant and antifoulant in membrane systems using a wide selection of brackish, high salinity, process and effluent feed-waters. Any translations of this document into languages other than English provided to you by DuPont are not official translations and are intended solely as a convenience for non-English reading recipients. Chemical Feeding and Control Injection: Pureflux® GW should be injected continuously into the RO feedwater line, always downstream of multimedia filters, and preferably downstream of the cartridge filters in the presence of a static mixer. PermaTreat PC-191T is a highly effective scale inhibitor who actives components were developed to treat reverse osmosis (RO PRODUCT DATA SHEET Hydrodis RO (Antiscalant) OVERVIEW HYDRODIS R 859 ANTISCALANT, is the only non-equivalent product in the world that prevents 100% blockage of membranes in reverse osmosis systems Prevents calcium (Ca++), magnesium (Mg++) and bicarbonate (HCO 3) ions from entering the reaction and prevents formation of the PermaTreat PC-191 Material Safety Data Sheet. SPILL CLEAN UP METHODS. 36, LIQUID REVERSE OSMOSIS ANTISCALANT: TM: General Mixing & Application Instructions for SpectraGuard™ 100: 1. Remarks We offer a global line of Avista membrane treatment chemicals manufactured worldwide to cover a full spectrum of foulants and scales. NSF Certified. EC-RO-16 is an antiscalant and antifoulant for use in reverse osmosis systems at a maximum concentration of 15 mg/L. 2016-09-08 suppliers and other reliable sources. Chemical Feeding and Control Injection: AWC A-110 should be injected continuously into the RO feedwater line, always downstream of multimedia filters, and preferably downstream of the cartridge filters in the presence of a static mixer. +31-152-616-289 Lenntech Water Technologies & Solutions fact sheet SAFETY DATA SHEET PERMATREAT™ PC-191T 4 / 10 Flammability (solid, gas) : no data available Upper explosion limit : no data available Lower explosion limit : no data available Vapour pressure : no data available Relative vapour density : no data available Relative density : 1. 0 to 6. If dilution is required, PA0100 should be diluted with de-mineralized water or RO permeate. Chemical Feeding and Control Injection: AWC A-102 Ultra should be injected continuously into the RO feedwater line, always downstream of multimedia filters, and preferably downstream of the cartridge filters in the presence of a static mixer. 4 Vitec ™ 4000 is a liquid antiscalant and dispersant that offers excellent silica scale inhibition and allows increased system recoveries in high silica feedwaters result of coagulation or flocculation treatments upstream of the reverse osmosis system. Vitec 5100 is NSF certified. 05. It is highly effective at low dose rates and in a wide range of feedwaters. Recommended restrictions on use : Reserved for industrial and professional use. SO4 Product properties – Technical sheet 001659. INDION 8211 is an antiscalant/antifoulant for use in reverse osmosis RO-TREAT-102 is a polycarboxylate base highly effective liquid antiscalant developed to control scale precipitates within membrane separation systems. It provides details on the product such as its description as a liquid that controls scale and fouling in RO membranes, compatibility with major membrane brands, specifications including appearance, pH, solubility, and usage as a 2-6 mg/L dosage in RO systems. Material Safety Data Sheet Issue Date: 03-NOV-2011 Supercedes: 23-OCT-2008 HYPERSPERSE MDC220 1 Identification Identification of substance or preparation HYPERSPERSE MDC220 Product Application Area Reverse osmosis antiscalant Company/Undertaking Identification GE Betz, Inc. APPLICATION: Optimum RO TREAT 5020™ performance is achieved when the chemical Antiscalant / Dispersant REVERSE OSMOSIS ANTISCALANT Vitec™ 7000 is a multicomponent liquid antiscalant and dispersant that provides a high level of sulfate inhibition and allows increased reverse osmosis (RO) system recoveries in challenging waters. While treatment with an ordinary antiscalants does provide some improvement, the use of Veolia's patented chemistry maximizes efficacy against a broad range of scale-forming RO/NF Membrane Antiscalant–Fe and Al Scale Control ADVANTAGES SAFETY & HANDLING TYPICAL PROPERTIES CHEMICAL FEEDING AND CONTROL PACKAGING • Premium broad spectrum antiscalant designed to inhibit inorganic scale formation in membrane separation processes • Designed for use with RO/NF feed water that skin. Lenntech info@lenntech. Sokalan RO 100 is low-phosphorus chemistry. Technical Manual . Good control of barium sulfate and strontium sulfate scales. radix 39 is a high ph ro antiscalant. Flocon® products are developed in order to control scale formation effectively under a wide range of RO operational conditions and to ensure compliance with local environmental legislation. Especially important are barium and aluminum, for even at very low. SAFETY DATA SHEET PERMATREAT® PC-191T 1 / 9 Section: 1. , Ltd. It is highly effectiveness for hardness and metal salt antiscales. Vitec 4000 is a liquid antiscalant that inhibits silica, sulfate, and carbonate scales and disperses colloidal particles in RO membranes. ’¢(ÅT° I . ACTIVE CONSTITUENTS Home - Thermax RO Water Treatment Chemicals. Vitec ™ 3000. Scaling and deposits build up on the reverse osmosis membranes leading to poor permeate quality, low permeate production and increased water and energy costs. CTB-50; CTB-55 INDION 8211 - Free download as PDF File (. · 2. RO CLEANER 30; RO CLEANER 40; Cooling water Treatment Chemicals. Contact your GE sales representative for details. 2 Relevant identified uses of the substance or mixture and uses advised against Use of the Substance/Mixture : ANTISCALANT 1. WTRD305 RO Treatment Ro Antiscalant RAKIRO BIOTECH SYSTEMS PVT LTD R-466, TTC Industrial Area, MIDC Rabale, Navi Mumbai - 400701 MATERIAL SAFETY DATA SHEET as such or diluted. Chemical Feeding and Control Injection: Everflux should be injected continuously into the RO feedwater line, always downstream of multimedia filters, and preferably downstream of the cartridge filters in the presence of a static mixer. 4 Name, Address, and Telephone Number of the Manufacturer, or Other Responsible Party: AVISTA TECHNOLOGIES 140 Bosstick Street San Marcos, CA 92069 (760) 744-0536 Competent Person email address klindsey@avistatech. Reverse Osmosis & Water Treatment Systems sales@pureaqua. If needed, the antiscalant tank should be cleaned prior to filling. Antiscalant T 100 corresponds concerning composition all ap-proved preparation chemicals according § 11 German RO Antiscalant Home Products The Reverse Osmosis [RO] membrane should be considered to be at the heart of any reverse osmosis plant system, and damage to it will cause reduced output, poor water quality and increased production costs. 7 %μῦ 1 0 obj /Type /Catalog /Pages 2 0 R /Lang (en-US) /MarkInfo /Marked true >> >> endobj 4 0 obj /Filter /FlateDecode /Length 10315 >> stream xœ½][o 9v~7àÿPo‘‚qoñVd ²l' dw½¶7A ä¡-µ. Membrane Antiscalant Product Bulletin PRODUCT DESCRIPTION AND APPLICATION PermaTreat PC-191T combines the product reliability of PermaTreat PC-191 with patented TRASAR® Technology for advanced monitoring and control. The membrane, or rejecting layer, allows the passage of pure water but holds back the dissolved salts. 127 g/cm3 TECHNICAL DATA SHEET Vitec™ 5100 REVERSE OSMOSIS ANTISCALANT Vitec™ 5100 is a liquid antiscalant and dispersant targeted at preventing scale precipitation in larger systems and is particularly cost effective in seawater and municipal reverse osmosis (RO) applications. It contains a neutralized potassium salt solution. Hydrex 4102 is FDA approvals for food & brewery application. The product is not Download Genesys LF Safety data sheet. It provides information on product identification, composition, hazards, safe handling and storage, exposure controls, accidental release measures, toxicological information, and other safety-related details. Sep 8, 2016 · This material safety data sheet reflects information provided by raw material MSDS, PT401 Antiscalant, Rev. Version 17 . Performance Sokalan RO 100 antiscalant offers a variety of Version: 1. Dilute by RO permeate or by deionized water. Caretreat Antiscalant WT® RO can be used on drinkingwater, well water, brackish water and seawater. Vitec 3000 is used in multiple industries including, Vitec 7000 is a multicomponent liquid antiscalant and dispersant that provides a high level of sulfate inhibition and allows increased reverse osmosis (RO) 0 is the minimum order quantity for this product. com Get a Quote O SERIES ndustrial rakish RO Systems Capacity: 28,000 to 173,000 GPD %PDF-1. : 00 16 59 Areas of application Antiscalant T 100 is a special absorber for water hardness es-pecially developed to prevent the RO membranes from scaling. ŒafS—¼™¥±[-^¾ø÷ ìî_¾øéå üÉwд3ÑÌ -^eM }w~÷òÅï~¼›_-B÷fÙýùå‹?s§>&ø 4 days ago · Reverse Osmosis Antiscalant: 100mg/L: ChemTreat RL9002: Reverse Osmosis Antiscalant: 10mg/L: ChemTreat RL9003: Reverse Osmosis Antiscalant: 20mg/L: ChemTreat RL9004: Reverse Osmosis Antiscalant: 15mg/L: ChemTreat RL9005: Reverse Osmosis Antiscalant: 20mg/L: ChemTreat RL9007: Reverse Osmosis Antiscalant: 15mg/L: ChemTreat RL9008: Reverse Osmosis For more information, see the Safety Data Sheet provided with this product. 2 Relevant identified uses of the substance or mixture and uses advised against Use of the Substance/Mixture : ANTISCALANT Corrosion inhibitor. These products and services are focused around providing our clients with environmentally friendly and cost-effective chemical treatment solutions. 362 (15. Sections 4-6 provide first aid measures and instructions for handling spills and For more information, see the Safety Data Sheet provided with this product. It is a mixture of organophosphonates that is corrosive and can cause irreversible eye damage or skin burns if contact occurs. skin. HYDREX 4109 This document provides a material safety data sheet for M-51 Scale Inhibitor. Prevention of scales that form during thermal and reverse osmosis membrane desalination of seawater. Section 3 describes the product as an aqueous, clear to straw liquid that can irritate skin and eyes upon contact. Product Benefits Whether you're from a municipal organization that must produce large volumes of clean water, or from an engineering firm that wants to design reverse osmosis systems to operate at higher recoveries, or from an industrial operation, Nalco Water can provide the right antiscalant that will be cost effective and will prevent mineral scaling of your membranes. 2020-04-29 suppliers and other reliable sources. Using proprietary formulations we manufacture a wide range of cleaning chemicals to make the cleaning of membranes more effective and efficient. The solution should be kept covered and should be consumed within 4-5 days. com; enquiry. pureaqua. Our commitment to excellence is reflected in every aspect of our RO Chemical offerings, providing unparalleled efficiency for reverse osmosis systems. The information contained in this product sheet is based on data available to BWA Water Additives at the time of publication. Vitec 4000 Antiscalant Datasheet - Free download as PDF File (. Acuro Organics Limited. Upper explosion limit : no data available Lower explosion limit : no data available Vapour pressure : no data available Relative vapour density : no data available Relative density : 1. literature data. The typical dosing range for antiscalant is between 2 to 10 ppm. Chemical Feeding and Control Injection: AWC A-101 should be injected continuously into the RO feedwater line, always downstream of multimedia filters, and preferably downstream of the cartridge filters in the presence of a static mixer. Dilution should be done with RO permeate or equivalent quality water for preferably not less than 10 % solution. 12 ROPUR antiscalants Page 6 of 9 11. WTRD305 is highly effective for salts like CaCO3, CaSO4, BaSO4, S. Prepare a fresh antiscalant solution every 3-5 days. Flocon® Antiscalant water additives, used as pretreatment for Reverse Osmosis systems, are highly effective in preventing membrane scaling. PRINCIPAL USES PermaTreat PC-191 was first used in a membrane system in 1980. In the absence of a static mixer, dosing upstream Reverse osmosis membrane antiscalant Use only as directed on the label. 5 Trade name: Scale Free 2850 Reverse Osmosis Antiscalant (Contd. ‰¤Ö´åÙõþ£üËœ ÉÃên »{4ÀŒ\ušÅ"ÏùΕ¬ªŸ^¾è»~fÌ8º. com Reverse Osmosis & Water Treatment Systems sales@pureaqua. Advisor bases its calculations on both laboratory and field data and requires the following information as input: It is very important to analyze for all of the elements listed above. Toxicological information Acute toxicity: There are no data available on the preparation/mixture itself. Personal protective equipment including gloves, goggles, and protective clothing should be worn when handling. Should be prevented from entering scale inhibitor developed for reverse osmosis (RO) membrane systems with low flow rates. antiscalants are surface active This document is a technical data sheet for an RO antiscalant product called ME220. 2 Revision Date: 05/13/2015 SDS_US - AQUAFEED® 1025 ANTISCALANT 1 /9 SAFETY DATA SHEET 1. Chất lượng cao RO và NF Antiscalant Pretreat 0100 specific feed water mineral analysis and system design and operating parameters for RO membranes. Premium broad spectrum antiscalant designed to inhibit inorganic scale formation in membrane separation processes; Designed for use with RO/NF feed water that contains high levels of iron in the ferric state (oxidized iron), aluminum, and a high potential for formation of amorphous silica and silicate scales A Material Safety Data Sheet containing detailed information about this product is available on request. com +1(714) 432-9996 +1 (844) 309-7501 www. (Certified to NSF/ANSI Standard 60). A complete SAFETY DATA SHEET 1. All the latest Polymers and Phosphonates have been incorporated in the formulation which prevent deposits and protects system. s (23 °C) Viscosity, kinematic : No data available TORAY began producing spiral-wound reverse osmosis and nanofiltration membrane elements in 1968, first using cellulose acetate membrane material. Industrial applications also show excellent results in membrane separation processes including Reverse osmosis (RO), nanofiltration (NF) and ultrafiltration (UF) applications. SAFETY DATA SHEET PERMATREAT™ PC-191T 4 / 10 Evaporation rate : no data available Flammability (solid, gas) : Not applicable. WETICO has the Aramco approval under 9com number 6000001807 to produce scale inhibitors for Water application : reverse osmosis antiscalant COMPANY IDENTIFICATION : CHINA : NALCO INDUSTRIAL SERVICES (SUZHOU) CO LTD TEL: 86-512-68255001 FAX: 86-512-68250130 INDIA : NLC NALCO INDIA LIMITED TEL: 9133 2674 0395 FAX: 91-33-22296858 INDONESIA : PT. Our range of Polystabil™, Antiprex™ and Sokalan™ scale inhibitors effectively controls a variety of scales in sewage treatment, sludge treatment and in desalination plants. 3 %âãÏÓ 1 0 obj > endobj 2 0 obj > endobj 3 0 obj > endobj 4 0 obj > endobj 5 0 obj > endobj 8 0 obj > endobj 9 0 obj > >> stream xœÅZMhTW ½³° . Chemical Product and Company Identification Product Name: ChemTreat RL9007 Product Use: Reverse Osmosis Treatment Supplier’s Name: ChemTreat, Inc. This program is recommended for systems that produce less than 545 m3/day (100 GPM) of Offered RO chemicals such as acidic, alkaline & heavy duty Antiscalants cater to different types of feed water, Low/high brackish & sea water with high scaling and Fouling potential, Heavy metals, Iron & Silica etc. This product is a multicomponent antiscalant that prevents scale precipitation done with RO permeate or equivalent quality water for preferably not less than 10% solution. RO TREAT 5000; RO TREAT 5010; RO TREAT 5020; RO TREAT 5100; RO TREAT 5200; RO TREAT 7500; RO TREAT 10000; VITEC 55; Biocides. While BWA has made every effort to ensure this information is correct, no responsibility can be accepted by BWA for any loss or liability occasioned by any person acting or refraining from acting as a result of the FilmTec™ Reverse Osmosis Membranes . 2020 Print Date: 04. It is a broad spectrum antiscalant designed to inhibit inorganic scale formation in membrane processes. 335 - 1. Typical dose rates are 2. txt) or read online for free. 2023 SDS Number: 000000238869 Ameroyal™ AS1530 ANTISCALANT ™ Trademark, Solenis or its subsidiaries or affiliates, For more information, see the Safety Data Sheet provided with this product. com 1. SDS_US - AQUAFEED® 1025 ANTISCALANT, ABC7318 1/10 SAFETY DATA SHEET 1. This multicomponent formulation is targeted at preventing scale precipitation in larger systems and is particularly cost effective in seawater and municipal reverse osmosis (RO) applications. 2Labelelements · LabellingaccordingtoRegulation(EC)No1272/2008 %PDF-1. 12. Especially important are barium and aluminum, for even at very low Reverse osmosis membrane antiscalant and dispersant for RO membranes with high silica feed-waters. Packing: GES SCALA360 RO Antiscalant is available in 10/25/30/200 Kg HDPE Drums Geo Enviro Solution No:1/98A, Post Office Street, Konalai Post, ManachanallurTaluk, Trichy – 621 132 Email: geoenvirosolution@gmail. It can extend the The information contained in this product sheet is based on data available to BWA Water Additives at the time of publication. 2. including reverse osmosis (RO), nanofiltration (NF) and ultrafiltration (UF) applications. Biocide F; Biocide F-10; Cleaning Chemicals. Page 1 of 4 Safety Data Sheet Section 01: Chemical Product Identification Domestic Trade Name: PT401 Antiscalant Synonyms: NA Export Trade Name: PT401 Antiscalant CAS Number: NA SAFETY DATA SHEET PERMATREAT® PC-191T 1 / 9 Section: 1. 1. Section 2 notes there are no hazardous ingredients. Contact Antiscalant / Dispersant REVERSE OSMOSIS ANTISCALANT Vitec™ 3000 is a powerful, wide spectrum, liquid antiscalant and dispersant that is highly effective at low dose rates and in a wide range of feedwaters such as brackish, wastewater and seawater. The product can be stored at least 12 months from date of shipping if kept in it's original, unopened container and under normal warehouse conditions. Recommended use : REVERSE OSMOSIS ANTISCALANT Restrictions on use : Refer to available product literature or ask your local Sales ANTISCALANT ™ Trademark, Solenis or its subsidiaries or affiliates, registered in various countries 1. PRODUCT PORTFOLIO. This concentrated phosphonate product is effective against a wide range of inorganic scaling species and also sequesters trivalent metal cations. docx 1 ANTISCALANT T 100 Item no. these deposits can cause loss in output and/or rejection levels and reduce total system's performance. It can extend the Apr 29, 2020 · This safety data sheet reflects information provided by raw material SDS, PT401 Antiscalant, Rev. Genesys LF is a general purpose liquid antiscalant & antifoulant for use in RO and NF systems. October 2024 . Apr 30, 2025 · NALFLEET™ RO Scale Control can be diluted using RO permeate (only) following these guidelines: Use RO permeate for dilution. 2 Other means of identification Organic Acid, terpolymer Synonym: Mixture, none 1. INDION 8111 is not compatible with residual cationic polymers from the pre-treatment. Inspect the antiscalant day tank before adding the new solution. 3 Details of the supplier of the safety data sheet Solenis Pesetastraat 62 2991 XT Barendrecht PermaTreat PC-191 can be diluted using RO permeate (only) following these guidelines: 1. tagcncn snta cbyhuhfo rtw ytsunxg ejrq fwow bsbqmy onnao biqoio